Elevator Air Conditioners

No-Drip Technology

Elevator cabins can easily become hot, noisy, and uncomfortable for passengers, especially in warm climates. To solve this problem, Dazen elevator air conditioners are specially designed for installation on top of elevator cabins, where space is limited and vibration is constant. Their compact structure, low noise operation, and vibration-resistant design ensure a comfortable riding experience without affecting elevator performance.

One of the biggest concerns when adding air conditioning to an elevator is condensation and water dripping. Our units use a secondary evaporation system that re-evaporates condensate during operation, so you don’t need to worry about water leakage inside the cabin or shaft.

With low energy consumption and compliance with CE and LVD standards, these units are reliable for long-term operation in demanding environments.

Whether you are working on a new elevator project or upgrading an existing one, simply share your cabin size and project location with us — we will recommend the most suitable model for you.

اطلب عرض أسعار سريع

Our Elevator Air Conditioner Models

Available in 1 HP, 1.5 HP, 2 HP, and 3 HP capacities, with options for cooling only, cooling & heating, and disinfection functions, you can select the configuration that best fits your project needs.

نموذجSmall 1PSmall 1P1P1PBig1PBig1P1.5P1.5pBig1.5pBig1.5p
FunctionCollingCooling and HeatingCollingCooling andHeatingCollingCooling andHeatingCollingCooling andHeatingCollingCooling andHeating
Heating type-Electric heating-Electric heating-Electric heating-Electric heating-Electric heating
Cooling capacity (W)1850士10%1850士10%2600士10%2600士10%2800士10%2800士10%3600士10%3600士10%3800士10%3800士10%
Power supply (V)220v-240v/50hz 1ph220v-240v/50hz 1ph220v-240v/50hz 1ph220v-240v/50hz 1ph220v-240v/50hz 1ph220v-240v/50hz 1ph220v-240v/50hz 1ph220v-240v/50hz 1ph220v-240v/50hz 1ph220v-240v/50hz 1ph
Rated power of refrigeration (W≤650≤650≤700≤700≤1000≤1000≤1015≤1015≤1200≤1200
Rated refrigeration input current (A)2.5A2.5A2.8A2.8A3.5A3.5A4.6A4.6A5A5A
Rated heating input current (A)-5.5A-5.5A-8.8A8.8A8.8A
Rated heating power (w)-1200W/H-≤2000W/H-≤2000W/H≤2000W/H≤2000W/H
Input voltage range (v)220v-240v/50hz220v-240v/50hz220v-240v/50hz220v-240v/50hz220v-240v/50hz220v-240v/50hz220v-240v/50hz 1ph220v-240v/50hz 1ph220v-240v/50hz 1ph220v-240v/50hz 1ph
RefrigerantR410/240gR410/240gR410/400gR410a/400gR410/400gR410/400gR410/480gR410/480gR410/500gR410/500g
Circulating air volume (m³/h)220m3/Hour220m3/Hour438m3/Hour438m3/Hour438m3/Hour438m3/Hour480m3/Hour480m3/Hour480m3/Hour480m3/Hour
Temperature setting range c)16-3116-3116-3116-3116-3116-3116-3116-3116-3116-31
Noise db(a42/5242/52<55<55<55<55<55<55<55<55
وضع التحكمRemote control/control panelRemote control/control panelRemote control/control panelRemote control/control panelRemote control/control panelRemote control/control panelRemote control/control panelRemote control/control panelRemote control/control panelRemote control/control panel
Electric shock protection typeClass IClass IClass IClass IClass IClass IClass IClass IClass IClass I
Waterproof gradeIPX4IPX4IPX4IPX4IPX4IPX4IPX4IPX4IPX4IPX4
Volume (m³)380*435*295(mm)380*435*295(mm)535*500*355(mm)535*500*355(mm)535*500*355(mm)535*500*355(mm)535*500*355(mm)535*500*355(mm)535*500*355(mm)535*500*355(mm)
الوزن (كجم)18192021222327293133
Weight of the accessory box (kg)6677777777
Applicable to elevators (kg300-800KG300-800KG300-800KG300-800KG800-1350KG800-1350KG1350KG and above1350KG and above1350KG and above1350KG and above

Tell us your cabin size, project country, and power supply — we will recommend the correct model.

الأسئلة الشائعة

Yes. Our elevator air conditioners comply with CE, EMC, LVD, and CCC standards. They are specifically engineered for elevator environments, ensuring stable, safe, and reliable operation.

Installation typically takes around 6 hours. We provide detailed installation instructions to help your technicians complete the process quickly and correctly.

Yes. Our products are designed for modernization projects and can be installed on existing elevators without modifying the shaft structure.

Our units are designed for low power consumption, allowing continuous operation without significantly increasing the elevator’s energy usage.

The normal operating temperature range is 16°C to 43°C. For environments beyond this range, performance may be affected. We can recommend suitable models based on your project location.